H05 RR-F/H05 RN-F Rubber-insulated flexible cable VDE-tested, harmonized design 

TECHNICAL DATA
  • Rubber  insulation
  • according to DIN VDE 0282 Part 4 HD 22.4 S3 ZZ IEC 60245-4
  • Temperature range -30° C to +60° C
  • Permissible operating temperature at the conductor +60° C
  • Rated voltage U0/U 300/500 V
  • max. permissible of three-phase and single-phase AC systems U0/U 318/550 V DC systems U0/U 413/825 V
  • Test voltage 2000 V
  • Minimum bending radius approx. 75x  cable diameter
  • Fire behaviour according to DIN VDE 0482 Part 265-2-1/EN 50265-2-1/IEC 60332-1 (complying with DIN VDE 0472 Part 804 Test Mode B)
  • Resistant to Ozone
Note
  • Can get get in touch with oil/grease
DESCRIPTION
  • Stranded copper wire, bright or tinned, fine wires according to DIN VDE 0295 Kl. 5, BS 6360 cl. 5, IEC 60228 or HD 383
  • Rubber wire insulation El4 according to DIN VDE 0282 Part 1
  • Wires stranded in layers
  • Wires coloured according to DIN VDE 0293 or HD 186
  • Black outer jacket for RR-F = Rubber, EM 3 according to DIN VDE 0282 Part 1
RN-F = NEOPRENE®1), EM 2 according to DIN VDE 0282 Part 1

APPLICATION

H05 RR-F according to DIN VDE 0282, Part 4
The cables are suitable for the connection of electrical equipment, e.g. vacuum cleaners, electric irons, soldering guns, kitchen equipment, toasters, cookers, etc.  They are also used in households and offices where low mechanical loads are prevailing.
The cables may be permanently laid in movable walls, furniture, decorative linings and cavities of prefabricated building components.
They are suitable for temporary outdoor installation, commercial companies  (but permitted in textile workshops, etc.) or farms and for the connection of commercial electric tools.

H05 RN-F according to DIN VDE 0282, Part 4
The cables are suitable for the connection of electrical equipment with low mechanical loads in dry, humid and wet rooms as well as outdoors, e.g. as con
necting cables for gardening tools. The cables may get in touch with grease and oil (e.g. deep fryers). They may also be permanently laid, e.g. in movable walls, furniture, decorative linings and cavities of prefabricated building components. H05 RN-F has been approved for installation in potentially explosive areas.

CE = The product complies with the EC Low-Voltage Directive 72/23/EWG or 93/68/EWG

G = with earthed conductor gn-ge
X = without earthed conductor

Note
  • H05 RR-F replaces the previous types NLH and NMH up to 2.5 mm2.
  • HOS RN-F replaces the previous type NMHöu up to 1 mm2.

* not specified by VDE; basically in compliance with VDE (H)05RN-F
** national type: A-05RN-F
*** (A)05 RN-F, jacket colour: grey Especially for manufacturers of blinds

Other dimensions and cross-sections on request.
No. of wires
Cross-section mm²
Outer dia. mm
min - max
Copper No.
kg/km
Weight
approx.  kg/km
2 x 0,75 5,7–7,4 14,4 60
2 x 1 6,1–8,0 19,0 72
2 x 1,5 7,6–9,8 29,0 98
       
3G0,75 6,2–8,1 21,6 74
3G1 6,5–8,5 29,0 85
3G1,5 8,0–10,4 43,0 120
3G2,5 9,6–12,4 72,0 170
       
4G0,75 6,8–8,8 29,0 78
4G1 7,1–9,3 38,0 98
4G1,5 9,0–11,6 58,0 150
4G2,5 10,7–13,8 96,0 220
       
5G1,5 9,8–12,7 72,0 180
5G2,5 11,9–15,3 120,0 270
       
2 x 0,75 5,7–7,4 14,4 78
2 x 1 6,1–8,0 19,0 94
       
3G0,75 6,2–8,1 21,6 94
3G1 6,5–8,5 29,0 114
3G1,5* 8,6–11,0 43,0 157
       
4G0,75** 6,8–8,8 29,0 90
4G0,75*** 6,8–8,8 29,0 90
       
5G1,5* 10,5–13,5 72,0 228